Modbus Keyword
==============
The modbus keyword can be used for matching on various properties of
Modbus requests.
There are three ways of using this keyword:
* matching on functions properties with the setting "function";
* matching on directly on data access with the setting "access";
* matching on unit identifier with the setting "unit" only or with the previous setting "function" or "access".
With the setting **function**, you can match on:
* an action based on a function code field and a sub-function code when applicable;
* one of three categories of Modbus functions;
* public functions that are publicly defined (setting "public")
* user-defined functions (setting "user")
* reserved functions that are dedicated to proprietary extensions of Modbus (keyword "reserved")
* one of the two sub-groups of public functions:
* assigned functions whose definition is already given in the Modbus specification (keyword "assigned");
* unassigned functions, which are reserved for future use (keyword "unassigned").
Syntax::
modbus: function <value>
modbus: function <value>, subfunction <value>
modbus: function [!] <assigned | unassigned | public | user | reserved | all>
Sign '!' is negation
Examples::
modbus: function 21 # Write File record function
modbus: function 4, subfunction 4 # Force Listen Only Mode (Diagnostics) function
modbus: function assigned # defined by Modbus Application Protocol Specification V1.1b3
modbus: function public # validated by the Modbus.org community
modbus: function user # internal use and not supported by the specification
modbus: function reserved # used by some companies for legacy products and not available for public use
modbus: function !reserved # every function but reserved function
With the **access** setting, you can match on:
* a type of data access (read or write);
* one of primary tables access (Discretes Input, Coils, Input Registers and Holding Registers);
* a range of addresses access;
* a written value.
Syntax::
modbus: access <read | write>
modbus: access read <discretes | coils | input | holding>
modbus: access read <discretes | coils | input | holding>, address <value>
modbus: access write < coils | holding>
modbus: access write < coils | holding>, address <value>
modbus: access write < coils | holding>, address <value>, value <value>
With _<value>_ setting matches on the address or value as it is being
accessed or written as follows::
address 100 # exactly address 100
address 100<>200 # greater than address 100 and smaller than address 200
address >100 # greater than address 100
address <100 # smaller than address 100
Examples::
modbus: access read # Read access
modbus: access write # Write access
modbus: access read input # Read access to Discretes Input table
modbus: access write coils # Write access to Coils table
modbus: access read discretes, address <100 # Read access at address smaller than 100 of Discretes Input table
modbus: access write holding, address 500, value >200 # Write value greater than 200 at address 500 of Holding Registers table
With the setting **unit**, you can match on:
* a MODBUS slave address of a remote device connected on the sub-network behind a bridge or a gateway. The destination IP address identifies the bridge itself and the bridge uses the MODBUS unit identifier to forward the request to the right slave device.
Syntax::
modbus: unit <value>
modbus: unit <value>, function <value>
modbus: unit <value>, function <value>, subfunction <value>
modbus: unit <value>, function [!] <assigned | unassigned | public | user | reserved | all>
modbus: unit <value>, access <read | write>
modbus: unit <value>, access read <discretes | coils | input | holding>
modbus: unit <value>, access read <discretes | coils | input | holding>, address <value>
modbus: unit <value>, access write < coils | holding>
modbus: unit <value>, access write < coils | holding>, address <value>
modbus: unit <value>, access write < coils | holding>, address <value>, value <value>
With _<value>_ setting matches on the address or value as it is being
accessed or written as follows::
unit 10 # exactly unit identifier 10
unit 10<>20 # greater than unit identifier 10 and smaller than unit identifier 20
unit >10 # greater than unit identifier 10
unit <10 # smaller than unit identifier 10
Examples::
modbus: unit 10 # Unit identifier 10
modbus: unit 10, function 21 # Unit identifier 10 and write File record function
modbus: unit 10, function 4, subfunction 4 # Unit identifier 10 and force Listen Only Mode (Diagnostics) function
modbus: unit 10, function assigned # Unit identifier 10 and assigned function
modbus: unit 10, function !reserved # Unit identifier 10 and every function but reserved function
modbus: unit 10, access read # Unit identifier 10 and Read access
modbus: unit 10, access write coils # Unit identifier 10 and Write access to Coils table
modbus: unit >10, access read discretes, address <100 # Greater than unit identifier 10 and Read access at address smaller than 100 of Discretes Input table
modbus: unit 10<>20, access write holding, address 500, value >200 # Greater than unit identifier 10 and smaller than unit identifier 20 and Write value greater than 200 at address 500 of Holding Registers table
(cf. http://www.modbus.org/docs/Modbus_Application_Protocol_V1_1b3.pdf)
**Note:** Address of read and write are starting at 1. So if your system
is using a start at 0, you need to add 1 the address values.
**Note:** According to MODBUS Messaging on TCP/IP Implementation Guide
V1.0b, it is recommended to keep the TCP connection opened with a
remote device and not to open and close it for each MODBUS/TCP
transaction. In that case, it is important to set the depth of the
stream reassembling as unlimited (stream.reassembly.depth: 0)
**Note:** According to MODBUS Messaging on TCP/IP Implementation Guide
V1.0b, the MODBUS slave device addresses on serial line are assigned from 1 to
247 (decimal). Address 0 is used as broadcast address.
(cf. http://www.modbus.org/docs/Modbus_Messaging_Implementation_Guide_V1_0b.pdf)
Paper and presentation (in french) on Modbus support are available :
http://www.ssi.gouv.fr/agence/publication/detection-dintrusion-dans-les-systemes-industriels-suricata-et-le-cas-modbus/
Per-value keywords
------------------
The following keywords match on single values of a Modbus transaction,
taken from the same fields the EVE ``modbus`` event logs. They all use
:ref:`unsigned integers <rules-integer-keywords>` and support ranges and
negation. In to-server direction they match on the request; in to-client
direction they match on the response, for the values a response carries.
Read requests are only matched in to-server direction, as a read response
carries data rather than an address and a quantity.
modbus.unit_id
~~~~~~~~~~~~~~
Match on the Modbus unit identifier, the address of a slave device
connected on a sub-network behind a bridge or gateway.
modbus.unit_id uses an :ref:`unsigned 8-bits integer <rules-integer-keywords>`.
Examples::
modbus.unit_id:10;
modbus.unit_id:>247;
modbus.transaction_id
~~~~~~~~~~~~~~~~~~~~~
Match on the Modbus/TCP transaction identifier used to pair requests
and responses.
modbus.transaction_id uses an
:ref:`unsigned 16-bits integer <rules-integer-keywords>`.
Example::
modbus.transaction_id:1;
modbus.protocol_id
~~~~~~~~~~~~~~~~~~
Match on the Modbus/TCP protocol identifier. The specification requires
this field to be 0, so a non-zero value is an anomaly.
modbus.protocol_id uses an
:ref:`unsigned 16-bits integer <rules-integer-keywords>`.
Example::
modbus.protocol_id:!0;
modbus.function
~~~~~~~~~~~~~~~
Match on the Modbus function code, as it is logged in ``function_raw``.
It can be specified as the integer value or as the function code name
logged in ``function_code``. Names are case insensitive and can be
negated with ``!``.
.. note::
Error responses carry the request function code with the highest bit
set (e.g. 136 for a failed function 8), so ``modbus.function:>127;``
matches any error response. ``function_code`` is logged without that
bit, so a name matches a request, and a response that is not an error,
but never an error response. Match those by value, with
``modbus.function:>127;`` or the raised code.
``Unknown`` is logged in ``function_code`` for every code that has no
name, so it does not identify one value and is not accepted here. The
codes it covers are still matched by value.
modbus.function uses an :ref:`unsigned 8-bits integer <rules-integer-keywords>`.
Syntax::
modbus.function:[op]<number>
modbus.function:[!]<name>
See ``suricata --list-keywords=json | jq '."modbus.function".enum_values'``
Where name is one of:
* RdCoils
* RdDiscreteInputs
* RdHoldRegs
* RdInputRegs
* WrSingleCoil
* WrSingleReg
* RdExcStatus
* Diagnostic
* Program484
* Poll484
* GetCommEventCtr
* GetCommEventLog
* ProgramController
* PollController
* WrMultCoils
* WrMultRegs
* ReportServerID
* Program884
* ResetCommLink
* RdFileRec
* WrFileRec
* MaskWrReg
* RdWrMultRegs
* RdFIFOQueue
* MEI
Examples::
modbus.function:8;
modbus.function:Diagnostic; # same as above
modbus.function:!RdCoils;
modbus.function:>127;
modbus.subfunction
~~~~~~~~~~~~~~~~~~
Match on the subfunction code of Modbus Diagnostics (function 8)
messages. It can be specified as the integer value or as the
subfunction name logged in ``diagnostic.code``. Names are case
insensitive and can be negated with ``!``.
.. note::
``Reserved`` is logged in ``diagnostic.code`` for every subfunction
that has no name, so it does not identify one value and is not
accepted here. Those subfunctions are still matched by value.
modbus.subfunction uses an
:ref:`unsigned 16-bits integer <rules-integer-keywords>`.
Syntax::
modbus.subfunction:[op]<number>
modbus.subfunction:[!]<name>
See ``suricata --list-keywords=json | jq '."modbus.subfunction".enum_values'``
Where name is one of:
* RetQueryData
* RestartCommOpt
* RetDiagReg
* ChangeInputDelimiter
* ForceListenOnlyMode
* ClearCtrDiagReg
* RetBusMsgCount
* RetBusCommErrCount
* RetBusExcErrCount
* RetServerMsgCount
* RetServerNoRespCount
* RetServerNAKCount
* RetServerBusyCount
* RetBusCharOverrunCount
* RetOverrunErrCount
* ClearOverrunCounterFlag
* GetClearPlusStats
Examples::
modbus.function:8; modbus.subfunction:4;
modbus.function:Diagnostic; modbus.subfunction:ForceListenOnlyMode;
modbus.exception_code
~~~~~~~~~~~~~~~~~~~~~
Match on the exception code of Modbus error responses. It can be
specified as the integer value or as the exception name logged in
``exception.code``. Names are case insensitive and can be negated with
``!``.
.. note::
``Unknown`` is logged in ``exception.code`` for every exception code
that has no name, so it does not identify one value and is not
accepted here. Those codes are still matched by value.
modbus.exception_code uses an
:ref:`unsigned 8-bits integer <rules-integer-keywords>`.
Syntax::
modbus.exception_code:[op]<number>
modbus.exception_code:[!]<name>
See ``suricata --list-keywords=json | jq '."modbus.exception_code".enum_values'``
Where name is one of:
* IllegalFunction
* IllegalDataAddr
* IllegalDataValue
* ServerDeviceFail
* Ack
* ServerDeviceBusy
* NegAck
* MemParityErr
* GatewayPathUnavailable
* GatewayTargetFailToResp
Examples::
modbus.exception_code:11;
modbus.exception_code:GatewayTargetFailToResp; # same as above
modbus.read.address
~~~~~~~~~~~~~~~~~~~
Match on the starting address of Modbus read requests.
Unlike the ``address`` option of the ``modbus`` keyword above, this
matches the raw protocol value as it is logged, without the +1 offset,
and matches only the starting address of an access rather than the
whole accessed range.
modbus.read.address uses an
:ref:`unsigned 16-bits integer <rules-integer-keywords>`.
Example::
modbus.read.address:1000;
modbus.read.quantity
~~~~~~~~~~~~~~~~~~~~
Match on the quantity of items in Modbus read requests.
modbus.read.quantity uses an
:ref:`unsigned 16-bits integer <rules-integer-keywords>`.
Example::
modbus.read.quantity:>1000;
modbus.write.address
~~~~~~~~~~~~~~~~~~~~
Match on the starting address of Modbus write accesses. In to-client
direction this matches the address echoed in write responses.
Unlike the ``address`` option of the ``modbus`` keyword above, this
matches the raw protocol value as it is logged, without the +1 offset,
and matches only the starting address of an access rather than the
whole accessed range.
modbus.write.address uses an
:ref:`unsigned 16-bits integer <rules-integer-keywords>`.
Example::
modbus.write.address:500;
modbus.write.quantity
~~~~~~~~~~~~~~~~~~~~~
Match on the quantity of items in Modbus multiple-write requests, as it
is logged in ``write.quantity``. In to-client direction this matches the
quantity echoed in multiple-write responses, which the protocol carries
in the value field and the log reports as ``write.data``.
modbus.write.quantity uses an
:ref:`unsigned 16-bits integer <rules-integer-keywords>`.
Example::
modbus.write.quantity:>100;
modbus.write.value
~~~~~~~~~~~~~~~~~~
Match on the value of Modbus single-write accesses, as it is logged in
``write.data``. In to-client direction this matches the value echoed in
single-write responses.
.. note::
Multiple-write responses are not matched, as they echo a quantity
rather than a value (see ``modbus.write.quantity``).
modbus.write.value uses an
:ref:`unsigned 16-bits integer <rules-integer-keywords>`.
Example::
modbus.write.address:500; modbus.write.value:>200;